ARC 2713 lecture alignment — 6 November 2026
Evidence reviewed
All 15 supplied Zoom links were accessed and their complete available transcripts read. Key steel-floor slides were checked visually to resolve the office load and girder-load-pattern ambiguity. This was not a continuous viewing of every video minute. Two supplied links contain the same 213 transcript rows for the September 17 truss tutorial. Recording-access tokens are intentionally not copied into this public repository.
| Supplied link order | Lecture date | Content | Lab relationship |
|---|---|---|---|
| 1 | Oct 6 | Steel roof | Deck span, joist spacing, girder panel points, ASD and self-weight |
| 2 | Sep 29 | Wood project completion | Lateral system, column classes, foundations, assembly and evidence |
| 3 | Aug 25 | Structural origins/hierarchy | Bay, surface, secondary/primary member, vertical supports |
| 4 | Aug 27 | Bay morphology | One/two-way action, direction changes, removal of supports |
| 5 | Sep 1 | Equilibrium and stability | Force/moment equilibrium, diaphragm and two-axis lateral paths |
| 6 | Sep 3 | Loads | Tributary area, psf/plf/force units, self-weight and reactions |
| 7 | Sep 8 | Force and deformation | Axial force, bending, stress/strain, exaggerated deformation |
| 8 | Sep 15 | Wood roof | MPP → purlin → truss; node coordination |
| 9, 10 | Sep 17 | Same truss tutorial | Economy targets, member forces and model evidence |
| 11 | Sep 22 | Wood floor | Partial floor, clear span, panel seams, beam/girder/column coordination |
| 12 | Oct 13 | Steel floor/lateral | Partial floor options, composite deck, discrete girder loads |
| 13 | Oct 20 | Steel columns/foundations | Coordinate-specific loads, restraint and foundation records |
| 14 | Oct 27 | Concrete introduction | Precast systems and initial prototype constraints |
| 15 | Nov 3 | Concrete project update | Final prototype modifications and coordinated assembly |
Teaching decisions
- Design from the smallest spanning element outward; distinguish this from foundations-up construction assembly.
- Preserve wood office live load 50 psf and steel office live load 65 psf. The latter is visible in the Oct 13 slide at 11:37. Grocery/library use 75/150 psf in both floor assignments.
- Preserve wood soil assumption 3,000 psf versus steel 1,500 psf. Bearing area P/q is not footing-thickness design. Classroom examples are not universal approvals.
- Keep deck/table self-weight accounting separate from downstream load accounting. A capacity table that includes panel self-weight does not remove that weight from the supporting member.
- Preserve the existing correction of
40LH13(13 = section number), three-span deck = four supports, ASD/live-load checks, and girder weight versus panel-load units. - Preserve discrete two-third-point loading for a girder with three equal spaces. The Oct 13 calculator screenshot at 32:23 uses a midpoint example, whose result cannot verify the two-point case. Existing W18×44 invalid-designation guidance remains intact.
- Retain partial floors and double-height voids. Require actual headers, collectors, connections and lateral paths in the coordinated model; a rendered frame does not verify these conditions.
- Retain compression-blue/tension-red force meanings, adjusted for visibility on medium gray. Displayed deformations remain illustrative and amplified.
- Add concise stage evidence and a course sequence guide, with the same guidance available to the local Coach knowledge retrieval.
- Add a concrete briefing bridge using Oct 27 and Nov 3. The concrete workspace still explicitly identifies its elastic-study scope; no unverified precast capacity tables or full project model were invented.
Interaction repairs
- Shared
#666666canvas background, charcoal interface, warmer annotation cards, brighter role/force colors. Opaque member fills maintain at least 3:1 contrast to the background. Thin members use brighter outlines. - Floor bay and whole-building models use the same elevation and nominal W-section depth inputs. The preview is flush-top and schematic, as stated in the course guide.
- Every foundation-stage column has a unique support-coordinate picking ID. Selection uses existing per-column records; no duplicate overlay column is added.
- Roof, floor and foundation re-renders retain camera position within the same view scope; Fit, plan/3D and whole-building/bay switches establish an appropriate new view.
- Floor model annotations now render using the shared steel annotation renderer.
- Source tasks open the original PDF/calculation workspace alongside the live conditions panel. It replaces the model area instead of obscuring the controls. Closing stays respected during same-step edits.
- Column-only/foundation views suppress unrelated roof/floor labels. Course guide and checkpoint disclosures keep the full original task navigation available.
Verification
Existing suites: steel-roof.test.cjs (including 360 assignment/spacing combinations), steel-explain.test.cjs, steel-linked-tables.test.cjs, studio-regression.test.cjs.
New suite: lecture-alignment.test.cjs checks 80 linked roof/floor combinations for matching elevations/depths, all support IDs, camera snapshot isolation, palette contrast and course/Coach load distinctions.
Browser checks: actual PDF cell selection updates deck gauge and self-weight; Save/Open restores that choice; roof-to-floor flow preserves the shared brief; partial-floor model and local bay respond to elevation changes; clicking another column changes the grid record; course guide opens with the correct stage-specific evidence. Publication is checked against the live site after deployment.
Wood original-table integration — 6 November 2026
- Added original pages from Lecture 6 (69, 79) and Lecture 7 (44, 34). Their PDF page content was copied without redrawing tables and verified pixel-identical to the source.
wood-sources/provenance.jsonrecords source page numbers, Drive URLs and full-source SHA-256 hashes. - Transparent buttons map the three assigned roof and floor load conditions, the course purlin column for spans 6–15 ft, and the four floor-panel widths. Source rows outside these assignment choices remain readable in the complete page.
- Roof MPP clicks set the shared use/location, target purlin spacing and linked nodal loads. The actual spacing is computed from the top-chord nodes and shown separately. Purlin clicks set both roof and truss frame spacing. Floor clicks set beam centers from the governing clear span plus beam width; panel-width clicks change actual subdivisions.
- The printed 8.44 ft F10-3 vibration limit is checked separately from the live-load columns. The default applied floor span uses the smaller limit. End seams and the partial floor remain coordinated.
- The lecture’s fixed 3.5 × 9.5 in purlin uses 8 plf. Alternative sections retain the explicit 35 pcf estimate. MPP self-weight is counted once in the downstream roof load.
- The simple-span purlin model applies the Simple row (12 ft: 665 plf). Clicking Multiple (12 ft: 510 plf) explains the support mismatch without mutating or approving the model. Economy criteria are shown separately from capacity checks.
- Save/Open retains canonical cell IDs; geometry, dead-load and occupancy changes are checked against the saved conditions. No capacity or provenance is trusted from imported free text.
- The supplied course folder
12IsQijuLbxPMHX6nKry2rk11cVsA6wYAconfirms these original Lecture 6 and Lecture 7 sources. Lecture 8 and the assignment template reuse the same three span/load tables; beam, girder and column sizes are calculation exercises rather than additional span/load lookup tables.
Validation: wood-tables.test.cjs covers all three briefs, all ten supported purlin spans, four widths, conservation of roof/floor loads, rejected support mismatches, and saved-source validation. Existing model, steel, studio and lecture-alignment suites also pass. Browser checks exercise actual PDF cells, shared model updates and Save/Open.