Concrete beam sections — 10 November 2026

Code commit: 1feb9bacd4d4107e4936c91ace9e10ef05955858.

Source requirements

The original Parameters & Prototypes PDF, pages 14, 15 and 17, permits L, T or rectangular beams for ALPHA, CHARLIE and KILO. Page 16 specifies DELTA deck and vertical systems without prescribing a beam family. The app exposes all three shapes; the default schematic arrangement is an inward-facing L at a one-sided perimeter support and an inverted T at an internal two-sided support. This is a modeled support arrangement, not a claim that the assignment mandates one particular beam family.

The original Precast Span & Load Tables PDF is retained: rectangular beams p.12, L-shaped beams p.13, inverted T beams p.14. No capacities were replaced with invented values.

Implemented behavior

Validation

36 automated tests passed, 0 failed. Full output: BEAM_TEST_RESULTS.txt. Tests cover all four prototypes and all three shapes, inward L orientations, non-overlapping section solids, deck clearance, dimensional application, load and reaction conservation, saved-state migration and existing Wood / Steel / renderer regressions.

Browser checks in the local preview:

Service-table comparisons do not complete connection, reinforcement, lateral stability, camber, bearing-pad or soil design. The interface preserves these scope limits and source footnotes.

Actual browser Save study / Open study round-trip also passed: a saved DELTA paired-L selection was restored after changing the live shape to rectangular, with independent edge source records retained.